# Record Preweld Temperatures in WeldCloud Assembly

Record Preweld Temperatures in WeldCloud Assembly using the "Send to Machine" option inside a Weld. You can also record inter-pass temperatures by updating the parameter after each pass. This data can be cross-checked in WeldCloud Fleet.

## Procedure

1. Go to the desired Weld and click **"Send to Machine..."**

   ![Go to Weld and click Send to Machine](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step01-go-to-weld-and-click-se_k59ybk.jpeg)

2. Click on the machine you want to use for this weld, then click the **"WPS Parameter ID *"** field to select it

   ![Click machine and WPS Parameter ID](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step02-click-machine-and-wps-p_1qkrenz.jpeg)

3. Click the **"WPS Parameter ID *"** field

   ![Click WPS Parameter ID field](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step03-click-wps-parameter-id-_1uoojlb.jpeg)

4. Select the appropriate WPS Parameter from the list

   ![Select WPS Parameter](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step04-click-here_139iusz.jpeg)

5. Click the **"Preweld temperature (°C)"** field and enter the temperature value

   ![Click Preweld temperature field](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step05-click-preweld-temperatu_ecowb.jpeg)

6. Click **"Send to machine"**

   ![Click Send to machine](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step06-click-send-to-machine_14zrpdb.jpeg)

7. You can check the recorded temperature in WeldCloud Fleet by clicking the Fleet link — it takes you directly to the Fleet page of the selected machine

   ![Check in WeldCloud Fleet](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step07-check-in-weldcloud-flee_13zik29.jpeg)

8. Click the back button to return to the weld

   ![Click back](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step08-click-here-to-go-back_1e4ny5a.jpeg)

9. After going back to the same Weld, if you have multiple Parameters, click **"Change Parameter"** to enter a new Preweld Temperature — this will be considered as the Inter-pass Temperature. The next parameter will be automatically selected

   ![Click Change Parameter](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step09-click-change-parameter_edhf0v.jpeg)

10. Click the **"Preweld temperature (°C)"** field and enter the new temperature

    ![Enter new temperature](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step10-enter-new-preweld-tempe_u8czd5.jpeg)

11. Click **"Update parameter"**

    ![Click Update parameter](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step11-click-update-parameter_12kj6qm.jpeg)

12. Return to the same Weld in WeldCloud Assembly, click **"Change Parameter"** to enter another Inter-pass Temperature

    ![Return to Weld and Change Parameter](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step12-return-to-weld-and-chan_1033u8g.jpeg)

13. Click the **"Preweld temperature (°C)"** field and enter the temperature

    ![Enter temperature](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step13-enter-temperature-field_2eibc.jpeg)

14. Click **"Update parameter"** to register the changes

    ![Click Update parameter](https://storage.crisp.chat/users/helpdesk/website/-/1/c/b/d/1cbda94eeb4b4100/step14-click-update-parameter-_1di7uc5.jpeg)