Articles on: Onboarding

How to connect ESAB EDGE system to WeldCloud using gateway web interface

Connect via Wi-Fi


Step-by-step walkthrough for connecting an ESAB Warrior EDGE system to WeldCloud by accessing the gateway's web configuration page over Ethernet and configuring WiFi connectivity. 12 steps.


Prerequisites



Procedure


  1. Turn on welding equipment and wait 2 minutes for gateway to boot
  2. Connect your PC and welding equipment through Ethernet cable



    Connect PC to EDGE via Ethernet
  3. Open browser and navigate to esab.local:8080 (or esab.local:8443 (HTTPS) for EDGE software package LP14 and later)
  4. Enter credentials and click "Login" — default username: admin, password: gateway



    Login with default credentials
  5. You will be forced to change the default gateway password — choose your password and fill in twice, then click "Save new password"



    Change default password
  6. Click "Configuration"



    Click Configuration
  7. Click to open Wi-Fi details



    Open Wi-Fi details
  8. Pick your wireless network, type the password, and click "Connect"



    Connect to WiFi network
  9. Check Wi-Fi network connection status on the gateway page



    WiFi connection status
  10. Click "WeldCloud configuration"


Click WeldCloud configuration


  1. Click on "Browse" button and load the configuration file downloaded previously


Browse and load config file


  1. Click "Save changes"


Save changes


  1. Check WeldCloud connectivity status


WeldCloud connectivity status


Connect via wired connection


Step-by-step walkthrough for connecting an ESAB Warrior EDGE system to WeldCloud by accessing the gateway's web configuration page over Ethernet and configuring wired network connectivity. 12 steps.


Prerequisites


  • ESAB Warrior EDGE system
  • PC with Ethernet port and Ethernet cable
  • Asset pre-created in WeldCloud with configuration file downloaded
  • Active InduSuite account with WeldCloud license
  • At least one Site created in WeldCloud


Procedure


  1. Turn on welding equipment and wait 2 minutes for gateway to boot
  2. Connect your PC and welding equipment through Ethernet cable



    Connect PC to EDGE via Ethernet
  3. Open browser and navigate to esab.local:8080 (or esab.local:8443 (HTTPS) for EDGE software package LP14 and later)
  4. Enter credentials and click "Login" — default username: admin, password: gateway



    Login with default credentials
  5. You will be forced to change the default gateway password — choose your password and fill in twice, then click "Save new password"



    Change default password
  6. Click "Configuration"



    Click Configuration
  7. Click to expand wired configuration settings



    Expand wired settings
  8. Select IP assignment — use Dynamic (DHCP) for most network environments



    Select Dynamic IP assignment
  9. Click "Save changes"



    Save network changes
  10. Click "WeldCloud configuration"


Click WeldCloud configuration


  1. Click on "Browse" button and load the configuration file downloaded previously


Browse and load config file


  1. Click "Save changes"


Save changes


  1. Disconnect your laptop from the EDGE and connect the EDGE to your wired network


Connect EDGE to wired network