How to factory reset Compulab gateway in case of a lost password, using a USB stick
This aricle explains how to factory reset Standalone i.MX8 gateway using a USB stick.
Please ensure following requirements are met:
- USB stick formatted as FAT32
Reset procedure
- Create an empty file on your computer with name .perform_factory_reset
1. Launch Notepad on Windows

2. Click "File"
3. Click "Save As..."
4. Write ".perform_factory_reset" in File name field. Please make sure to include quotes both at the beginning and at the end

5. Click "Save"
6. Now you should have on your Desktop a filled called .perform_factory_reset

- Copy file created in USB stick root
- Power off Standalone i.MX8 gateway
- Insert USB stick in one of the available USB ports on the gateway

- Turn on Standalone i.MX8 gateway and wait 2 minutes
- Power off Standalone i.MX8 gateway and remove USB stick
- Power on Standalone i.MX8 gateway and access with default credentials (username: admin, password: gateway)